Inspection
1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the PCSV connector.
|
3. |
Measure resistance between the PCSV terminals 1 and 2.
|
4. |
Check that the resistance is within the specification.
|
Removal
1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the purge control solenoid valve connector (A).
|
3. |
Disconnect the vapor hoses (B) from the purge control solenoid
valve.
|
4. |
Remove the valve after removing the bolt (C).
|
Installation
|
|
1. |
Installation is reverse of removal.
|
Purge Control Solenoid Valve (PCSV). Schematic Diagrams
Circuit Diagram
...
Auto Light Sensor. Repair procedures
Inspection
In the state of IGN1 ON, when multifunction switch module detects auto
light switch on, tail lamp relay output and head lamp low relay output are controlled
according to auto ligh ...
Description and Operation
Warning Lamp Activation
Warning Lamp Behavior after Ignition
On
As soon as the operating voltage is applied to the SRSCM ignition input,
the SRSCM activates the warning lamp fo ...